• Lien vers X
  • Lien vers Facebook
  • English English Anglais en
  • Italiano Italiano Italien it
  • Français Français Français fr
  • Deutsch Deutsch Allemand de
TÉLÉCHARGER
lifeherotile
  • HOME
  • LIFEHEROTILE
    • RÉSULTATS ET AVANTAGES
    • ACTIVITÉS
      • PROBLÈME CIBLE
      • SOLUTION PROPOSÉE
      • LES BÉNÉFICIAIRES
  • NETWORKING
  • AVANCEMENT
    • Les résultats du projet
    • L’état du projet
  • ÉVÉNEMENTS
  • PRESSE
  • BULLETTIN
  • LES CONTACTS
  • Cliquez pour ouvrir le champ de recherche Cliquez pour ouvrir le champ de recherche Rechercher
  • Menu Menu

Archive pour la catégorie : News

Vous êtes ici : Accueil1 / News

Study Visit

4 octobre 2016/dans News

Study Visit at LIFE HEROTILE mock-up building of the Hungarian LIFE National Contact Point TEAM, within the “LIFE Capacity Building in Hungary” Project and with the participation of the Italian Ministry of the Environment.

Study Visit

https://www.lifeherotile.eu/wp-content/uploads/2016/09/20160928_180453-1.jpg 675 1200 Silvia Zambelli https://www.lifeherotile.eu/wp-content/uploads/2017/07/banner-sito-life-herotile.png Silvia Zambelli2016-10-04 14:45:072016-10-04 14:59:55STUDY VISIT AT LIFE HEROTILE MOCK-UP BUILDING

Click here to download

4 octobre 2016/dans News
https://www.lifeherotile.eu/wp-content/uploads/2016/10/LIGEHT.jpg 525 804 Silvia Zambelli https://www.lifeherotile.eu/wp-content/uploads/2017/07/banner-sito-life-herotile.png Silvia Zambelli2016-10-04 14:33:032016-10-04 14:43:08Download new Noticeboard

COMSOL CONFERENCE 2016 – Munich

4 octobre 2016/dans News

The design of a novel roof tile shape using CFD analysis

Michele Bottarelli*1,Marco Bortoloni1, Giuseppe Dino1

1University of Ferrara, Department of Architecture, Italy

*corresponding author: [email protected]

 

In climates with high temperature and solar radiation, reducing the cooling consumption and increasing the standards of indoor comfort are topics of great importance. The roof plays a key role in controlling the indoor thermal comfort, due to its size in comparison with the other components of a building envelope and the direct exposure to solar radiation. The arrangement of the covering elements on a battens and counter-battens system allows creating a ventilation layer under the tiles in the tiled pitched roof. This so-called Above Sheathing Ventilation (ASV) helps to dissipate the excess heat during the summer, reducing the heat transfer between tiles and roof structure below, thereby also reducing the cooling energy requirement. In ventilated roofs, air flow within the ASV depends on the air entering and leaving at the eaves and the ridge, according to external wind conditions. Moreover, in tiled roofs the air-permeability of the overlapping tiles is an additional and diffuse intake/exhaust air-vent system therefore, the benefits of ASV could be enhanced by increasing the roof air permeability by means of novel tile shapes. That is the main idea of the HEROTILE European project (LIFE14 CCA/IT/000939), of which this work presents the preliminary analysis supporting the design of new tiles.

In this study, in order to support the design of novel Marseillaise tile shapes, the air permeability of newly designed tile was compared with that of the reference tile, under different wind directions and intensities. The reference tile shapes as well as the novel one were imported in COMSOL Multiphysics from CAD drawings by means of the CAD Import Module. The CFD Module of COMSOL Multiphysics was used to simulate the airflow through the tiles, solving the steady-state, incompressible, turbulent fluid dynamic problem in a three dimensional domain by means of the RANS-based standard k-e model. A parametric study was conducted to analyse the air flow variation in a ventilated pitched roof: four incident wind velocities (0.5, 1.0, 2.0, 5.0m/s) were considered, with three vertical (10°, 20°, 30°) and six horizontal inclinations (0°, 15°, 30°, 45°, 60°, 80°). Overall, 72 wind conditions over a simplified pitched roof were simulated.

The reference and new tile designs were compared in terms of the air pressure drop and the volumetric flow rate trough tiles. Preliminary results showed that new Marseillaise shape produced a small improvement in the air permeability and that some solutions were less affected by the wind direction. A flow rate increase through the novel shaped tiles was related to both the enlarged open area between the tiles and the original design of the head lock. In view of this, the head lock design was further improved, yielding an increase in air permeability of up to 100% in comparison with the standard designs. Therefore, both these aspects should be considered in designing a novel Marseillaise tile shape. Moreover, contrary to the standard shape, the final design showed an increase in the air flow rate as the wind blows sideways.

COMSOL CONFERENCE 2016

https://www.lifeherotile.eu/wp-content/uploads/2016/10/consol.jpg 210 489 Silvia Zambelli https://www.lifeherotile.eu/wp-content/uploads/2017/07/banner-sito-life-herotile.png Silvia Zambelli2016-10-04 14:29:002016-10-04 14:29:00COMSOL CONFERENCE 2016 – Munich

https://www.lifeherotile.eu/wp-content/uploads/2016/09/merged-1.pdf

14 septembre 2016/dans News, Press Release
https://www.lifeherotile.eu/wp-content/uploads/2016/09/LATERIZIDITALIA.jpg 228 274 Silvia Zambelli https://www.lifeherotile.eu/wp-content/uploads/2017/07/banner-sito-life-herotile.png Silvia Zambelli2016-09-14 15:49:032016-10-04 14:54:53LATERIZI D’ITALIA – PROGETTO EUROPEO LIFE HEROTILE

Latest News

  • PROGETTARE IL TETTO “HEROTILE” CON “SENSAPIRO” 3 novembre 2018
  • Herotile, la tegola super-ventilata in cotto per un’estate più fresca 6 septembre 2018
  • Ultime dal progetto Life Herotile: l’evoluzione della tegola in laterizio 25 juillet 2018

Search

Search Search

With the contribution of the LIFE financial instrument of the European Community
Click on both images to see the meteorological stations built in Ferrara (ITALY) and Yeruham (ISRAEL)
© Copyright - lifeherotile - Powered by Warrant Group - powered by Enfold WordPress Theme
Faire défiler vers le haut Faire défiler vers le haut Faire défiler vers le haut
This website uses cookies to improve your experience. We'll assume you're ok with this, but you can opt-out if you wish.Accept Read More
Privacy & Cookies Policy

Privacy Overview

This website uses cookies to improve your experience while you navigate through the website. Out of these, the cookies that are categorized as necessary are stored on your browser as they are essential for the working of basic functionalities of the website. We also use third-party cookies that help us analyze and understand how you use this website. These cookies will be stored in your browser only with your consent. You also have the option to opt-out of these cookies. But opting out of some of these cookies may affect your browsing experience.
Necessary
Toujours activé
Necessary cookies are absolutely essential for the website to function properly. This category only includes cookies that ensures basic functionalities and security features of the website. These cookies do not store any personal information.
Non-necessary
Any cookies that may not be particularly necessary for the website to function and is used specifically to collect user personal data via analytics, ads, other embedded contents are termed as non-necessary cookies. It is mandatory to procure user consent prior to running these cookies on your website.
Enregistrer & appliquer